Patient monitor,Ultrasound,Sonography,Veterinary ultrasound
 
  Products >> Multiparameter Patient Monitor(for Human Use)
Multiparameter Patient Monitor (BW3A)    

BW3A.pdf


Products Information:
Features
¡ô 10.4" color TFT LCD display
¡ô Attractive streamline outline design, portable, compact and lightweight
¡ô Operation menu with multi-language interface selection: English, Spanish, Portuguese,  Chinese, French, German ¡­¡­
¡ô  Big Font Display
¡ô ST segment Analysis and Apnea Alarm function
¡ô Drug Dose Calculation and OXCRG Software
¡ô 72-hour tabular and graphic trends and data storage
¡ô High energy Li-ion battery for short-term transport and temporary power-down
¡ô Networking Capability. WAN communication function to network with central monitoring system and make  long-distance monitoring, diagnosis, maintenance and software upgrade possible
¡ô Linux Operation System
¡ô External display(VGA interface) and external printer connectible to record tabular and graphic trend
¡ô Dynamic Monitoring of blood pressure
¡ô Intelligent audio and visual alarm
¡ô Application: Adult, Pediatric and Neonate
¡ô Pacemaker detection and Arrhythmia Analysis( Optional)
 
Technical Specs:
 
ECG
Input: 5 lead ECG cable 
Lead section: lead ¢ñ,¢ò,¢ó/ aVR, aVL, aVF/ V
Gain£¨mm/mV£©: 1/4£¬1/2£¬1£¬2£¬4
Frequency response:     Diagnosis          0.05 - 100Hz
                     Monitor mode       0.5 - 40 Hz
                     Surgery            1.0 - 25 Hz
Sweep speed (mm/sec): 12.5, 25, 50
Heart rate range: 20-254 BPM
ST segment deviation analysis: -0.8-+0.8mV
Protection: Against electrosurgical interference and defibrillation
 
NIBP
Method: Automatic Oscillometric
Measurement range: Systolic  4.0 - 37.0 kPa
                 Diastolic 1.3 - 33.0 kPa
                 Mean 2.6 - 35.0 kPa
Scale: mmHg/Kpa
Operating Mode: Manual/Auto/STAT
Over pressure Protection:  Yes
 
SPO2
Measurement range: 0 - 100 %
Pulse Rate range:   30- 254BPM
Accuracy:         ¡À 2 %
Probe:            For Neonate, pediatric, and adult
 
Temperature
Channel: Two Channels
Measurement range: 29- 45¡æ
Accuracy: ¡À0.1¡æ
Scale: Celsius/Fahrenheit
 
RESP.
Method: Impedance
Measurement range: 0 - 120 BPM
Lead Connection: RA & LL or RA & RA
 
Power requirements 
Input: 98¡«260 V AC, 50/60Hz
Consumption: ¡Ü  80VA 
 
Safety standards:  GB9706.1¡¡ IEC  60601-1¡¡UL  544
 
EtCO2( Optional)
Method: Side Stream
Measurement range: 0 % - 10.0 % in CO2 and et CO2£©
Display: Waveform, Respiration Rate, EtCO2, FiCO2
Scale: mmHg/Kpa
 
2-IBP ( Optional)
Channel: 2 Channels
Parameter: SYS/DIA/MAP/Pulse Rate
Scale: mmHg/kPa
 
Recorder (Optional)
Type: Built-in Thermal Recorder
Print Mode: Waveform and/or Text
 
 


 
TOP
 
   
  We offer sonography,ultrasound, patient monitor and veterinary ultrasound etc.
  Copyright 2009 © Bondway Electronics Co., Ltd All Rights Reserved.Offer Patient monitor,Veterinary ultrasound etc.
TEL:86-755-86224650 26400367 29163253 29163260  FAX:86-755-26522952 29163263